Aiphone NEM-10/20/40A/C Master Station

10, 20, 40 Call with Handset

Description

Features

  • 10/20/40 stations call system 
  • Handset auto voice actuation used for private communication and press-to-talk for open voice communication 
  • Tone and LED call-in, stays lit until master answers 
  • Built-in All Call function 
  • Multiple subs calling, selectively call up to 10 sub stations 
  • Pre-tone at sub for notification upon being selected 
  • Minimized crosstalk and secured voice volume 
  • Two conductor wiring per sub, home run or multi-conductor cable run 
  • Can be used with IER-2 call extension speaker (available separately) 
  • Accessories available separately for health care applications 
  • Sub station can call dual NEM masters simultaneously 

Specifications

Maximum Output

500 mW at NEM with adj. receive volume

500 mW at sub station with adj. transmit volume

Call Alerts

Intermittent tremolo tone and lit LED, held until answered at master

Pre-tone and voice at sub station

Communication

Open voice, pres-to-talk and handset voice-actuation

Output

All Call Output:

6 W (up to 20 substations)

2 W (21 to 40 substations)

3 W (per 10 substations random selected)

Wiring

2 wires per NA substation (1 for common E line)

 

Wiring Distance:

420′ (128 m) with 22 AWG (Φ 0.65 mm) cable

650.0′ (198.1 m) with 20 AWG (Φ 0.8 mm) cable

1,000.0′ (304.8 m) with 18 AWG (Φ 1.0 mm) cable

Power Source

24 VDC

Maximum Power Consumption

45 W

4 W in standby

Compatible Power Supplies

PS-24E DC Power Supply (available separately) recommended

Operating Temperature

32 to 104°F (0 to 40°C)

Dimensions (H x W x D (NEM-10/C|NEM-20/C | NEM-40/C)

7.00 x 17.63 x 10.25″ (177.80 x 447.68 x 260.35 mm)  | 7.00 x 17.63 x 10.25″ (177.80 x 447.68 x 260.35 mm) | 7.00 x 23.25 x 10.25″ (177.80 x 590.55 x 260.35 mm)

Weight(NEM-10/C|NEM-20/C | NEM-40/C)

12.13 lb (5.50 kg)  | 13.23 lb (6.00 kg)  | 17.64 lb (8.00 kg)

Blog Navigation