Description
Features
- RS-485 LAN connectivity
- Reader options to control Doors, Lifts, Areas and User Logon
- Supports Wiegand card readers up to 88bits
- Reader outputs with individual self-resetting over current protection
- UniBus in-cabinet expansion interface
- Dedicated lock power input
- External Integriti power supply connection
- Full monitoring of external Integriti power supply
- Heavy duty lock relays
- Reader Valid & Invalid outputs per reader
- Door reed & tongue sense inputs per door
- Door request to enter & exit inputs per door
- DOTL relay outputs per door
- Dedicated cabinet tamper input
- Small PCB size 200 x 95mm
- Remote firmware upgrade over-the-wire
- Salto Sallis integration – up to 8 Doors via dedicated RS-485 reader port
- Doors & Expansion Options
- Expandable to 8 Doors (2 Doors on board)
- Expandable to 8 Wiegand Readers (2 Readers on board)
- Five enclosure size options provide 2, 4, 6 or 8 Door/Reader configurations
- Three plug on external power supply options (2A, 3A or 8A Switchmode)
- Lift button I/O interfacing via optional UniBus Lift interface card** (Up to 96 Floors)
- Expandable to 16 RS-485 readers via the dedicated RS-485 reader port (If Salto Integration is not being used)
- Offline Intelligence
- Offline intelligence provided for all Wiegand readers and standard lock outputs
- Offline Access Control database for 100,000 users
- Offline time periods
- Offline event database of 100,000 events
** Product under development at time of publication.
Specifications
Physical
- Enclosure Options:
- Small – 995200PEI Series – 252(L) x 358(W) x 85(D) (mm) (with 2Amp PSU – houses 2 doors)
- Medium – 995201PEI Series – 460(L) x 358(W) x 85(D) (mm) (with 3Amp PSU – houses up to 4 doors)
- XLarge – 995203PEI Series – 702(L) x 358(W) x 85(D) (mm) (with 3Amp PSU – houses up to 8 doors)
- XLarge – 995203PE8 Series – 702(L) x 358(W) x 85(D) (mm) (with 8Amp PSU – houses up to 8 doors)
- WideBody – 995204PE8 Series – 580(L) x 510(W) x 95(D) (mm) (with 8Amp PSU houses up to 8 doors)
- Rack Mount – 995220PEI Series – 2RU 680(L) x 420(W) x 85(D) (mm) (with 3Amp PSU – houses up to 8 doors)
- PCB Size Code: Integriti “B” size
- PCB Dimensions: 200(L) x 94(W) x 45(D) (mm)
- Weight: 8.2 k.g. (Based on medium enclosure, mains transformer, 7AH battery and cover)
- Installation Environment: 0ºC – 40ºC @15% – 85% Relative humidity (non-condensing)
Electrical (For PCB Only)
- Current Consumption: 110mA standby. 175mA with lock relays on
NOTE: Current consumption does not include the current required by readers or other external devices such as locks, buzzers, lamps or any device attached to the DOTL, Valid, Invalid, RS-485 Reader and UniBus connections - Over Current Protection: Reader +V connections. Protected with self resetting PTC’s
- Power Supply Input: 11V to 14VDC
Contact Ratings
- DOTL Relays: 1 Amp @ 30VDC (Door Open Too Long output)
- Lock Relays: 5 Amps @ 30VDC
Connections
- Lock 1 & 2: Includes Lock+, Lock-, NO/COM/NC
- Door 1 & 2: Includes Reed, 2 x 0v, Tongue, REN, REX, DOTL contacts
- Wiegand Reader 1 & 2: Includes Valid, Invalid, 0V, Reader+, D1, D0, ARM
- Lock Power: Includes Lock+, Lock- connections from external PSU
- Cabinet Tamper: 2 pin connection for cabinet tamper switch
- UniBus Port: 1 x UniBus Host expansion port
- RS-485 LAN: 1, Includes LAN+, LAN-, A, B. (LAN addressing set via DIP switches)
- RS-485 Reader: 1 (Serial reader interface – under development at time of publication)
External Power Supply Monitoring (Compatible with IR SMART PSU Devices)
- AC Fail: External PS AC Fail
- Low Battery: External PS Low Battery
- LAN Fuse: External PS LAN Fuse
- Detector Fuse: External PS Detector Fuse
- Low Volts: External PS Low Volts
- PSU Fail: External PS Fail