Inner Range 996091PCB&K Power Supply

3 Amp PSU, PCB & Kit

Categories: , ,

Description

Features

  • High Level monitoring of PSU Status (With Integriti Modules)
  • Quick-Connect PSU interface (For Integriti modules)
  • Separate battery charger output
  • Deep Discharge battery protection
  • Battery reverse polarity protection
  • Smart Fuse protection
  • Universal low level status outputs – AC Fail & Batt Fail
  • Seperate DC output connection
  • 16VAC Input (A 4Amp transformer is required)

Specifications

Physical

  • Size: 95(L) x 95(W) x 45(D) (mm)
  • Mounting: 4 x M3 screws to Inner Range chassis clips
  • Installation Environment: 0ºC – 50ºC @15% – 90% relative humidity (non-condensing)
  • Working Temperature Range: -25ºC to +50ºC ambient unforced ventilation

High Level PSU Status Monitoring
(Available when connected to Integriti LAN modules via 10-way Quick-Connect cable)

  • Status Alarms:
    • AC Failure, Power Supply Low Volts, Battery Fault, Battery Low, Battery Not
      Present, Power Supply Failure, LAN+ Smart Fuse Tripped, Detector+ Smart Fuse
      Tripped, Battery Failed Test, Trigger Battery Test

Battery Alarm Thresholds

  • Low Battery Alarm: 11.0VDC
  • Deep Discharge Protection: 10.4VDC
  • Recovery From Deep Discharge: 12.2VDC

Connections

  • Outputs:
    • 10-way Quick-Connect socket for Integriti modules
      1 x DET +/- 13.75VDC & 1 x LAN +/- 13.75VDC
      Battery charger connection (for 12V lead acid battery)
      Low-level AC Failure output (open collector output)
      Low-level Battery Fail output (open collector output)
      External Earth terminal for connection to enclosure
  • Inputs: Start Battery Test Input Trigger (zero volt dry contact input)

LED Indicators

  • Status Indicators: AC OK
    Battery Charging
  • Fault Indicators: Battery Fault
    Fault on DET+ Connection
    Fault on LAN + Connection

Power Specifications

  • Input Voltage: 16VAC, 50hz
  • Input Current: 3Amp with 4Amp transformer fitted and LK1 jumper fitted
    1.5Amp with 1.5Amp plug-pack fitted and LK1 jumper removed
  • Output Voltage: 13.75V DC +/-5%, up to 3Amp. (battery fully charged)
  • Max Output Current: 3Amp with LK1 fitted
    1Amp with LK1 removed
  • Switching Frequency: 370 kHz. approx.
  • Load Regulation: +0 / -500mV @ Iout = 0.1A to 3.0A
  • Conversion Efficiency: 85%. approx
  • Output Ripple: < 100mVRMS @ full load

Battery Types

  • Recommended Battery: 1 x 7Ah, 9Ah or 18Ah 12V Sealed Lead Acid Only