Takex TAK-PVW12TE Speaker

Voice Warning Sensor, 2 x 8 Second recordable messages

Description

Features

  • Wide angle 12m 90° lens
  • Pointable through 180°
  • Adjustable lux level sensor for selectable day and/or night operation
  • Masking kit supplied
  • Selectable N.O or N.C output
  • Speaker volume control up to 90dB
  • Built-in microphone or line input for recording 2 separate fully recordable messages (1 x day, 1 x night)
  • Remote arm/disarm
  • Wall or Pole Mount at 0.8 – 1.2m
  • 234 x 80 x 91mm
  • 12 – 30V DC, 55 – 300 mA

Specifications

Model PVW-12TE
Detection system Passive infrared
Coverage Horizontal coverage
Max. detection distance: 40′ (12m)    Horizontal detection zone: 7 zones
Detection angle: 90°                          Downward detection zone: 7 zones
Adjustment range Horizontal: ±90Degree  {±3Degree of fine adjustment is available)
Detection distance: 10’to 40′(3 to 12m)
(By adjusting vertical angle of downward curtain)
Supply voltage 10 to 30VDC (Non polarity)
Current consumption 55mA MAX. for standby
300mA MAX. for operation (When Max. volume)
ARM/DISARM input N.O./N.C. selectable with a switch
N.O.: Armed when closed
N.C.: Armed when opened
Response time: 300msec or longer
Input resistance: 1kQ or less
Replay input N.O./N.C. selectable with a switch
N.O.: Armed when closed
N.C.: Armed when opened
Response time: 300msec or longer
Input resistance: 1kQ or less
Day light control Recognized as night when the illuminance of the surrounding area is lower than the set illuminance.
Contact output Dry contact relay output N.O./N.C. selectable with a switch
Contact capacity: 30V (AC/DC), 0.5A MAX.
Contact operation: One shot operation Approx. 2sec.
Sound output Replay the two different messages through the built-in speaker Operation: off delay operation
Repeat sounds during detection time + Approx. 2sec. to 5min. Output sounds: [Message 1] and [Message 2] (Max. 8sec. each) Sound volume adjustment: 80dB Max. Recording method: Built-in microphone or Jack input
Operation LED Red LED
Blinks for warming-up – LED can be disabled with a switch.
Lights for detection – LED can be disabled with a switch.
Fast blinks for recording standby
Lights for recording (Max. 8sec.)
Tamper output Dry contact relay output: NC Capacity: 30V (AC/DC), 0.5A MAX.
Pulse count settings Once / Three times (Selectable with a switch) 
Sensitivity adjustment 30% to 170% (By potentiometer)
Connection Terminals
Ambient temperature – 4° F to + 122° F (- 20°C to + 50°C)
Mounting position Indoor / Outdoor (Rain-proof)
Weight 16.8oz(480g)
Appearance Body: AES resin     Lens: PE resin

Blog Navigation